HSE2 is a double mechanical seal in a balanced, semi-cartridge, stationary-based, multi-spring design. It is a direct replacement for pumps fitted with John Crane Safematic® Safeseal Type SE2. Seal faces are lubricated by a pressurised (barrier) or non-pressurised (buffer) fluid via e.g. a John Crane Safeunit™ seal water control device.
It is suitable for Sulzer AHLSTAR™ APP and APT pumps fitted with the standard gland packing casing covers / seal chambers.
Temperature:
Pressure:
Speed:
-30°C to +121°C
< 15 bar, 220 psi, 1.5 MPa
< 20m/s, 4000 fpm
rpm < 1200000/(3.14 x D1)
¹Guide-values only (due to diversity of possible applications). Enquire for specific-use cases. Maximum values of each parameter cannot be applied together.
A
B
C
D
E
F
G
H
I
J
K
L
M
N
OP
Q
R
S
T
U
V
W
X
Y
Spacer Sleeve O-ring
Spacer Sleeve O-ring
Spacer Sleeve
Spacer Sleeve O-ring
Inb. Rotary O-ring
Inb. Rotary Holder
Inb. Rotary Face
Inb. Stationary Face
Inb. Stationary Holder
Seal Plate O-ring
Seal Plate O-ring
Seal Plate
Seal Plate O-ring
Flush Plug / Port
Seal Thrust Ring
Outb. Stationary O-ring
Outb. Stationary Holder
Drive Screw
Multi-Springs
Outb. Stationary Face
Outb. Rotary Face
Outb. Rotary Holder
Outb. Rotary O-ring
Drive Collar
Set Screws
Inb. Seal Faces:
Outb. Seal Faces:
Elastomer:
Metal Parts:
(SiC)/(SiC)
(SiC)/(SiC)
Viton®
316S.S.
Note: Drive collar configuration differs between sizes to accommodate OEM installation lengths
(_) refers to shrink fitted
EQUIVALENT
Sulzer TB2P
Safeseal SE2 / SE2-AP
LP-D-S32-D20
DATA SHEET
HSE2 - Data Sheet
OEM names, brands, model or part numbers are used solely for reference. Our components are engineered to deliver performance and service life equivalent to or exceeding that of OEM parts when correctly installed and appropriately applied. Sulzer® AHLSTAR is a registered trademark of its respective company. Pump Seal Supplies Pty Ltd are not representative of, nor affiliated with Sulzer® AHLSTAR.
INSTALLATION & OPERATION
Operation:
HSE2 is a double-acting mechanical seal. It requires seal water for operation. The sliding faces get their lubrication from seal water.
Note! Do not run the seal without seal water. Regulate the seal water flow to 0.5 - 3 L/min. Outcoming seal water temperature should not exceed 60°C. If the seal requires more cooling, increase the flow. Regulate the seal water pressure 2 bars (30 psi) higher than the product pressure to be sealed.
Installation:
1. With the shaft removed, slide the outboard rotary and drive collar (parts U - Y) onto the shaft up against the shaft shoulder and tighten the set screws (Y).
2. Slide the stationary assembly (parts H - T) onto the shaft.
3. Slide the inboard rotary and spacer sleeve assembly (parts A - G) onto the shaft.
4. Make sure the pipe connections are accessible
5. Install the complete shaft assembly onto the mounting studs (2) on the rear of the standard gland packing chamber casing cover (1) and bolt.
6. Tighten with the impeller (3)
7. Install the seal water connections.